| Menşe yeri: | Almanya |
|---|---|
| Marka adı: | Endress+Hauser |
| Sertifika: | CSA Gen. Purpose. |
| Model numarası: | COM (94) 528 final - Karakterler |
| Min sipariş miktarı: | 1 Adet |
| Fiyat: | negotiable |
| Ambalaj bilgileri: | Standart karton paketleme |
| Teslim süresi: | istek üzerine |
| Ödeme koşulları: | T/T |
| Yetenek temini: | Ayda 100 adet |
| Malzeme: | PC/ABS muhafazası | Boyut: | 247x170x115mm (9.63x6.63x4.48 inç) |
|---|---|---|---|
| Ölçüm İlkesi: | Amperometrik oksijen ölçümü | Uygulama: | Su, Atık su, proses, balık yetiştiriciliği |
| karakteristik: | Grafik ekranlı 4 telli verici. | Tasarım: | COS31/41/71 için PC/ABS'den yapılmış saha muhafazasındaki çözünmüş oksijen vericisi. |
| Giriş: | 1 kanallı verici. | Çıktı / iletişim: | 0/4-20mA, Hart, Profibus. |
| Vurgulamak: | Liquisys Endress Hauser Instruments,Endress Hauser Instruments COM253-DX0005,Dissolved oxygen transmitter 4 wire |
||
SPECIFICATIONS
Measuring principle:Amperometric oxygen measurement
Application:Water, Waste water, process, fish farming
Characteristic;4-wire transmitter with graphic display.
Design:Dissolved oxygen transmitter in a field housing made of PC/ABS for COS31/41/71.
Material:PC/ABS-housing
Dimension:247x170x115mm(9.63x6.63x4.48inch)
Temperature sensor:Display and current output.
Input:1-channel transmitter.
Output / communication:0/4-20mA, Hart, Profibus.
Additional certifications:CSA Gen. Purpose.
Field of application
Liquisys COM253 is a standard transmitter for use with COS41 and COS61 oxygen sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and calibration make configuration and operation fast and easy.
The Liquisys COM253 transmitter works with Oxymax COS41 and Oxymax COS61 dissolved oxygen sensors in environmental applications, such as:
O2 control in the aeration basin
O2 control and monitoring of drinking water
Surface water monitoring
Process water treatment and monitoring
O2 control in fish farming for optimum growth conditions
Liquisys COM253 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
PROFIBUS PA
More operational safety: Continuous process check system, customized alarm configuration, calibration plausibility check.
Reliable oxygen control: Current input for flow rate monitoring with controller shut off or for feedforward control.
Easy to operate and service: Simple single-point calibration in air, air-saturated water or in the medium, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, e.g. P(ID) controller, timer, etc., allow for flexible adaption to all processes.
Related Part Number:
|
COS41-2F |
|
COS41-4F |
|
CPM253-MR0105 |
|
FDU91-RG1AA |
|
FDU91-RG2AA |
|
COS61-A1F0 |
|
CUS71D-AA1A |
|
FMU42-APB2A22A |
|
FMU90-R11CA111AA3A |
|
FMU90-R11CA131AA3A |
|
COM253-WX0005 |
|
COS61D-AAA1A3 |
|
CPS11D-7BT2G |
|
FMU41-ARB2A2 |
|
FMU30-AAHEAAGGF |
|
CPS11D-7AA21 |
|
CPS71D-7TB21 |
|
CPS12D-7NA21 |
|
CPM223-PR0005 |
|
CUS52D-AA1AA3 |
|
FTL31-AA4U3BAWSJ |
|
CPS11D-7AS21 |
|
COS61-A2F0 |
|
CPS12D-7PA21 |
|
CPF81D-7LH11 |
|
CPS11D-7BA2G |
|
CPM253-PR0005 |
|
51518598 |
|
CM42-MEA000EAZ00 |
|
CUS51D-AAD1A3 |
|
CM442-AAM2A2F010A |
|
CM442-AAM1A2F011A+AK |
|
CYK10-G101 |
|
CYK10-G051 |
|
COY31-Z |
|
FMU30-AAHEABGHF |
|
COS61D-AAA1A4 |
|
CYK10-E051 |
|
CPS71D-7TB2G |
|
CLM253-CD0005 |
|
CM442-AAM1A2F010A |
|
FTW31-A2A5AA0A+1 L:600MM |
|
CPS31-1AC2ESA |
|
CPS31-1EC2ESA |
|
DK9CM-2 |
|
FTL41-AAA2AAAAA2CJAAAAJ L=1000MM |
|
CPS11-2AA2ESK |
|
FTM51-AGJ2L4A12AA L=2600MM |
|
PMP71-AAA2H21GAAAA |
|
CLM253-ID0005 |
|
COV45-41TN1 |
|
CPS11-2BA2ESA |
|
CPS77E-BA6BBU2 |
|
CLM223-CD0520 |
|
CPM253-MR8010 |
|
CYK10-E101 |
![]()