| تصویب: | IECEx ia IIC T6 Ga/Gb | منبع تغذیه؛ خروجی: | 2-سیم؛ HART 4-20mA |
|---|---|---|---|
| نمایش، عملیات: | SD02 4 خط، دکمه های فشاری + عملکرد پشتیبان گیری از داده ها | محفظه: | محفظه دوگانه GT20 ، ALU ، روکش شده |
| اتصال الکتریکی: | گلند M20، IP66/68 NEMA4X/6P | آنتن: | چکهکن، PTFE 50mm/2" |
| مهر و موم: | FKM Viton GLT، -40...130oC/-40...266oF | اتصال فرآیند: | نخ ISO228 G1-1/2, 316L |
| عملیات اضافی: | انگلیسی | کشور مبداء: | حرف |
| برجسته کردن: | FMR60 Radar Measurement Micropilot,Endress Hauser Radar Measurement Micropilot,Endress Hauser FMR60 Micropilot,Endress Hauser Radar Measurement Micropilot,Endress Hauser FMR60 Micropilot |
||
Micropilot FMR60 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. The free space radar offers maximum reliability due to the drip-off antenna, improved algorithms and small beam angle. It is used for continuous non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. It also possesses the smart sensor functionality Heartbeat Technology.
80GHz drip-off antenna suited for free space applications up to 50m and offers high beam focusing for vessels with many internal fittings.
Process connections: Threads or flanges
Temperature: –40 to +130°C (–40 to +266°F)
Pressure: –1 to +16bar (–14.5 to +232psi)
Maximum measuring range: 50m (164ft)
Accuracy: ±1mm (0.04in)
W-band: 80GHz
International explosion protection certificates, overfill prevention WHG, SIL, marine approvals, 5-point linearity protocol
|
Measuring principle |
Level radar |
|
Characteristic / Application |
For basic level measurement in liquids, pastes and slurries; |
|
Specialities |
Heartbeat Technology, |
|
Supply / Communication |
|
|
Frequency |
|
|
Accuracy |
+/- 1 mm (0.04 in) |
|
Ambient temperature |
|
|
Process temperature |
-40…+130 °C |
|
Process pressure / max. overpressure limit |
Vacuum …16 bar |
|
Main wetted parts |
PTFE antenna |
|
Process connection |
Thread: |
|
Max. measurement distance |
50 m (164 ft) |
|
Communication |
4…20 mA HART, |
|
Certificates / Approvals |
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex |
|
Safety approvals |
Overfill protection WHG |
|
Design approvals |
EN 10204-3.1 |
|
Options |
Display, |
|
Application limits |
|
![]()