| Menşe yeri: | Amerika |
|---|---|
| Marka adı: | Bently Nevada |
| Sertifika: | CE |
| Model numarası: | 991-06-XX-01-00 |
| Belge: | 990 and 991 Transmitter Hou...19.pdf |
| Min sipariş miktarı: | 1 adet |
| Fiyat: | negotiable |
| Ambalaj bilgileri: | Standart karton paketleme |
| Teslim süresi: | 12-16 hafta |
| Ödeme koşulları: | T/T |
| Yetenek temini: | Ayda 100 adet |
| Giriş: | 1 adet temassız 3300 NSv Yakınlık Probu ve uzatma kablosunu kabul eder. | Güç: | Verici terminalinde +12 ila +35 Vdc girişi gerektirir. |
|---|---|---|---|
| 4 ila 20 mA Sinyal Çıkışı: | 2 kablolu konfigürasyonda belirtilen tam ölçekli aralıkta 4 ila 20 mAdc. | 4 ila 20 mA Döngü Doğruluğu: | Belirtilen tam ölçek aralığının üzerinde ±%1,5 dahilinde (tipik). Doğruluk, TEST sinyal girişinden 2 |
| Maksimum döngü direnci: | 35 Vdc'de kablo dahil 1.000 Ω. | Akım Sınırlama: | 23 MA tipik |
| Vurgulamak: | 23 mA Limiting 991 Thrust Transmitter,Bently Nevada 991 Thrust Transmitter |
||
The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors or small pumps, motors, or fans who prefer to provide a simple 4 to 20 mA proportional axial displacement (thrust) signal as the input to their machinery control system. The transmitter is a 2-wire, loop-powered device that accepts input from our 3300 NSv proximity probe and its matching extension cable (available in 5 m and 7 m system length options). The transmitter conditions the signal into appropriate engineering units proportional to the shaft’s axial position1, and provides it as a 4 to 20 mA industry-standard signal for input to the control system where machinery protection alarming and logic occurs2.
The 991 transmitter provides the following notable features:
Integrated Proximitor Sensor requires no external unit
Non-isolated "PROX OUT " and "COM" terminals plus a coaxial connector provide a dynamic vibration and gap voltage signal output for diagnostics3.
Non-interacting zero and span potentiometers under the Transmitter label supports loop adjustment.
Test Input pin allows quick verification of loop signal output, using a variable DC voltage source as the input.
A Power-up Inhibit circuit eliminates signal errors due to line voltage transients.
A Not OK/Signal Defeat circuit prevents high outputs or false alarms due to a faulty proximity probe or loose connection.
Choice of DIN-rail clips or bulkhead mounting screws as standard options simplifies mounting.
Potted construction for high humidity (up to 100% condensing) environments.
Compatibility with 3300 NSv proximity probe allows transducer installation in small areas with minimal
Ordering Information
991-AA-BB-CC-DD
|
A: Full-scale Option |
|
|
06 |
0.6-0-0.6 mm |
|
25 |
25-0-25 mils |
|
B: System Length Option |
|
|
50 |
5.0 meters (16.4 feet) |
|
70 |
7.0 meters (23.0 feet) |
|
C: Mounting Option |
|
|
01 |
35 mm DIN-rail clips |
|
02 |
Bulkhead screws |
|
03 |
DIN clips and screws |
|
D: Agency Approval Option |
|
|
00 |
Not required |
|
01 |
CSA Division 2 |
|
05 |