| Material: | Sensor Body : POMMembrane Cap : POM | Dimension: | Diameter : 40mm (1.56inch)Length : 220mm (8.85inch) |
|---|---|---|---|
| Measuring Principle: | Amperometric Oxygen Measurement | Application: | Aeration Tank, River Monitoring, Water Treatment, Fish Farming. |
| Characteristic: | Amperometric 2-electrode System To Measure Dissolved Oxygen. | Design: | - Extreme Stable Membrane- Analog Communication |
| Process Temperature: | Max. 50°C (122°F) | Temperature Sensor: | Integrated NTC-sensor |
| Highlight: | endress hauser flow meter Oxymax,Dissolved oxygen sensor COS41-4F,Dissolved oxygen sensor |
||
SPECIFICATIONS
Measuring principle:Amperometric oxygen measurement
Application:Aeration tank, river monitoring, water treatment, fish farming.
Characteristic:Amperometric 2-electrode system to measure dissolved oxygen.
Measurement range:0,05 - 20mg/l
Measuring principle:Closed (membrane covered) amperometric 2-electrode sensor.
Design:- Extreme stable membrane- Analog communication
Material:ensor body : POMMembrane cap : POM
Dimension:Diameter : 40mm;(1.56inch)Length : 220mm(8.85inch)
Process temperature:max. 50°C(122°F)
Process pressure:max. 10bar(145psi)
Temperature sensor:Integrated NTC-sensor
Connection:Process connection : G1"Cable : Fixed cable or TOP68 connector
Field of application
Oxymax COS41 is a reliable and accurate oxygen sensor for all kinds of water & wastewater applications. Designed for reduced maintenance and a long operating life, the sensor offers real value for money.
Oxymax COS41 measures the dissolved oxygen concentration in:
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring
Fish farming:
- O2 control for optimum growth conditions
Benefits
High measurement accuracy
Long maintenance intervals
Minimum calibration effort thanks to simple air calibration
Related Part Number:
|
CYK10-A101 |
|
CYK10-A031 |
|
CYK10-A051 |
|
CPS11D-7BA21 |
|
CPM223-MR0005 |
|
CPM253-MR0005 |
|
CM442-AAM1A2F010A+AK |
|
COM223-DX0005 |
|
COM253-DX0005 |
|
CLM223-CD0005 |
|
COS41-2F |
|
COS41-4F |
|
CPM253-MR0105 |
|
FDU91-RG1AA |
|
FDU91-RG2AA |
|
COS61-A1F0 |
|
CUS71D-AA1A |
|
FMU42-APB2A22A |
|
FMU90-R11CA111AA3A |
|
FMU90-R11CA131AA3A |
|
COM253-WX0005 |
|
COS61D-AAA1A3 |
|
CPS11D-7BT2G |
|
FMU41-ARB2A2 |
|
FMU30-AAHEAAGGF |
|
CPS11D-7AA21 |
|
CPS71D-7TB21 |
|
CPS12D-7NA21 |
|
CPM223-PR0005 |
|
CUS52D-AA1AA3 |
|
FTL31-AA4U3BAWSJ |
|
CPS11D-7AS21 |
|
COS61-A2F0 |
|
CPS12D-7PA21 |
![]()