VIDEO China 3300 XL 8 Mm Bently Nevada Vibration Transmitter 330130-040-01-00 330130-040-01-CN

3300 XL 8 Mm Bently Nevada Vibration Transmitter 330130-040-01-00 330130-040-01-CN

Proximitor Sensor Input: Accepts One Non-contacting 3300-series 5 Mm, 3300 XL 8 Mm Proximity Probe And Extension Cable.
Power: Requires -17.5 Vdc To -26 Vdc When Installed With Nonincendive Circuit Connected Per Installation Drawing 140979 At 12 MA Maximum Consumption, -23 Vdc To -26 Vdc With Barriers. Operation At A More Positive Voltage Than -23.5 Vdc Can Result In Reduced Linea
Supply Sensitivity: Less Than 2 MV Change In Output Voltage Per Volt Change In Input Voltage.
VIDEO China TK-3E Bently Nevada Vibration Monitoring System TK3 Proximity System Test Kit 177313-01-01-00

TK-3E Bently Nevada Vibration Monitoring System TK3 Proximity System Test Kit 177313-01-01-00

Electric: 95-125 Vac, 50/60 Hz, 1A Minimum 190-250 Vac, 50/60 Hz, 1A Minimum
Air: 90 Psi (6.2 Bar) Maximum
Vibration Amplitude Range:: 50 μm To 254 μm (2 To 10 Mils) Peak-to-peak.
VIDEO China 3.94 MV/Mm/S Bently Nevada Vibration Monitoring 190501 Velomitor CT Transducer

3.94 MV/Mm/S Bently Nevada Vibration Monitoring 190501 Velomitor CT Transducer

Sensitivity: 3.94 MV/mm/s (100 MV/in/s) ±5%.
Frequency Response: 3.0 Hz To 900 Hz (180 To 54,000 Cpm) ±1.0 DB 1.5 Hz To 1.0 KHz (90 To 60,000 Cpm) ±3.0 DB
Temperature Sensitivity: -8% To +5% Typical Over The Operating Temperature Range
VIDEO China 20mAdc Bently Nevada Vibration Monitoring System 990 Vibration Transmitter  990-05-50-01-00

20mAdc Bently Nevada Vibration Monitoring System 990 Vibration Transmitter 990-05-50-01-00

Input: Accepts 1 Non-contacting 3300 NSv Proximity Probe And Extension Cable.
Power: Requires +12 To +35 Vdc Input At The Transmitter Terminal.
4 To 20 MA Signal Output: 4 To 20 MAdc Over Specified Fullscale Range In 2-wire Configuration.
China 18 To 36Vdc Bently Nevada Vibration 2300 Monitors 2300 / 20-00

18 To 36Vdc Bently Nevada Vibration 2300 Monitors 2300 / 20-00

DC Input: 18~36 Vdc, Max 7.5 W
Configurable Bandpass Filter: 0.2 Hz To 20 KHz
ScalFactor Range: 5 To 1000 MV/g
China 330750 330752 Bently Nevada Vibration Monitoring System High Temperature Velomitor System

330750 330752 Bently Nevada Vibration Monitoring System High Temperature Velomitor System

Sensitivity: 5.7 MV/mm/s (145 MV/in/s) ±5%
Frequency Response: 15 To 2000 Hz (900 To 120,000 Cpm) ± 3.0 DB; 20 To 1000 Hz (1,200 To 60,000 Cpm) ± 0.9 DB
Mounted Resonant Frequency: Greater Than 5 KHz
China 21000 Bently Nevada Vibration Monitoring System Proximity Probe Housing Assemblies

21000 Bently Nevada Vibration Monitoring System Proximity Probe Housing Assemblies

3300 XL 8mm Probe: Temperature Range -51°C To +177°C
3300 XL 11mm Probe: Temperature Range -51°C To +177°C
3300 NSv Probe Operating: -34°C To +177°C
China 20kHz Bently Nevada Vibration Monitoring System  200150 200155 200157 Accelerometers

20kHz Bently Nevada Vibration Monitoring System 200150 200155 200157 Accelerometers

Sensitivity @ 80 Hz (± 12%): 10.2 MV/(m/s2) (100 MV/g)
Mounted Resonant Frequency: >20 KHz (>1200 Kcpm)
Size: 17.5 Mm X 45.7 Mm (
VIDEO China 4.5Hz Bently Nevada Vibration Sensor Velomitor XA Piezo-Velocity Sensor 330525-CN   330525-00

4.5Hz Bently Nevada Vibration Sensor Velomitor XA Piezo-Velocity Sensor 330525-CN 330525-00

Sensitivity: Sensitivity
Frequency Response: 4.5 To 2,000 Hz (270 To 120,000 Cpm) ±3.0 DB, 6.0 To 1,000 Hz (360 To 60,000 Cpm) ±0.9 DB.
Weight: 156 G (5.5 Oz), Typical
VIDEO China 330101-00-05-10-02-00 17.5Vdc 26Vdc Bently Nevada Vibration Monitoring System 3300 Xl 8mm Proximity Transducer System

330101-00-05-10-02-00 17.5Vdc 26Vdc Bently Nevada Vibration Monitoring System 3300 Xl 8mm Proximity Transducer System

Proximitor Sensor Input: Accepts One Non-contacting 3300-series 5 Mm, 3300 XL 8 Mm Proximity Probe And Extension Cable.
Power: Requires -17.5 Vdc To -26 Vdc When Installed With Nonincendive Circuit Connected Per Installation Drawing 140979 At 12 MA Maximum Consumption, -23 Vdc To -26 Vdc With Barriers. Operation At A More Positive Voltage Than -23.5 Vdc Can Result In Reduced Linea
Supply Sensitivity: Less Than 2 MV Change In Output Voltage Per Volt Change In Input Voltage.
1 2 3 4 5 6 7 8