All Products
-
Bently Nevada Vibration Monitoring System
-
Bently Nevada 3500 System
-
Endress Hauser Instruments
-
AB Modules
-
P+F Sensors
-
YOKOGAWA Transmitter
-
Emerson Rosemount Transmitter
-
Emerson Micro Motion Flow Meters
-
Emerson AMS Trex Device Communicator
-
MTL Safety Barrier
-
ABB TZID Valve Positioner
-
SIEMENS Simatic PLC
-
Siemens Building Automation
-
VEGA Instrumentation
-
AUMA Actuator
-
HACH Water Quality Meter
3300 XL 8 Mm Bently Nevada Vibration Transmitter 330130-040-01-00 330130-040-01-CN
Proximitor Sensor Input: | Accepts One Non-contacting 3300-series 5 Mm, 3300 XL 8 Mm Proximity Probe And Extension Cable. |
---|---|
Power: | Requires -17.5 Vdc To -26 Vdc When Installed With Nonincendive Circuit Connected Per Installation Drawing 140979 At 12 MA Maximum Consumption, -23 Vdc To -26 Vdc With Barriers. Operation At A More Positive Voltage Than -23.5 Vdc Can Result In Reduced Linea |
Supply Sensitivity: | Less Than 2 MV Change In Output Voltage Per Volt Change In Input Voltage. |
TK-3E Bently Nevada Vibration Monitoring System TK3 Proximity System Test Kit 177313-01-01-00
Electric: | 95-125 Vac, 50/60 Hz, 1A Minimum 190-250 Vac, 50/60 Hz, 1A Minimum |
---|---|
Air: | 90 Psi (6.2 Bar) Maximum |
Vibration Amplitude Range:: | 50 μm To 254 μm (2 To 10 Mils) Peak-to-peak. |
3.94 MV/Mm/S Bently Nevada Vibration Monitoring 190501 Velomitor CT Transducer
Sensitivity: | 3.94 MV/mm/s (100 MV/in/s) ±5%. |
---|---|
Frequency Response: | 3.0 Hz To 900 Hz (180 To 54,000 Cpm) ±1.0 DB 1.5 Hz To 1.0 KHz (90 To 60,000 Cpm) ±3.0 DB |
Temperature Sensitivity: | -8% To +5% Typical Over The Operating Temperature Range |
20mAdc Bently Nevada Vibration Monitoring System 990 Vibration Transmitter 990-05-50-01-00
Input: | Accepts 1 Non-contacting 3300 NSv Proximity Probe And Extension Cable. |
---|---|
Power: | Requires +12 To +35 Vdc Input At The Transmitter Terminal. |
4 To 20 MA Signal Output: | 4 To 20 MAdc Over Specified Fullscale Range In 2-wire Configuration. |
18 To 36Vdc Bently Nevada Vibration 2300 Monitors 2300 / 20-00
DC Input: | 18~36 Vdc, Max 7.5 W |
---|---|
Configurable Bandpass Filter: | 0.2 Hz To 20 KHz |
ScalFactor Range: | 5 To 1000 MV/g |
330750 330752 Bently Nevada Vibration Monitoring System High Temperature Velomitor System
Sensitivity: | 5.7 MV/mm/s (145 MV/in/s) ±5% |
---|---|
Frequency Response: | 15 To 2000 Hz (900 To 120,000 Cpm) ± 3.0 DB; 20 To 1000 Hz (1,200 To 60,000 Cpm) ± 0.9 DB |
Mounted Resonant Frequency: | Greater Than 5 KHz |
21000 Bently Nevada Vibration Monitoring System Proximity Probe Housing Assemblies
3300 XL 8mm Probe: | Temperature Range -51°C To +177°C |
---|---|
3300 XL 11mm Probe: | Temperature Range -51°C To +177°C |
3300 NSv Probe Operating: | -34°C To +177°C |
20kHz Bently Nevada Vibration Monitoring System 200150 200155 200157 Accelerometers
Sensitivity @ 80 Hz (± 12%): | 10.2 MV/(m/s2) (100 MV/g) |
---|---|
Mounted Resonant Frequency: | >20 KHz (>1200 Kcpm) |
Size: | 17.5 Mm X 45.7 Mm ( |
4.5Hz Bently Nevada Vibration Sensor Velomitor XA Piezo-Velocity Sensor 330525-CN 330525-00
Sensitivity: | Sensitivity |
---|---|
Frequency Response: | 4.5 To 2,000 Hz (270 To 120,000 Cpm) ±3.0 DB, 6.0 To 1,000 Hz (360 To 60,000 Cpm) ±0.9 DB. |
Weight: | 156 G (5.5 Oz), Typical |
330101-00-05-10-02-00 17.5Vdc 26Vdc Bently Nevada Vibration Monitoring System 3300 Xl 8mm Proximity Transducer System
Proximitor Sensor Input: | Accepts One Non-contacting 3300-series 5 Mm, 3300 XL 8 Mm Proximity Probe And Extension Cable. |
---|---|
Power: | Requires -17.5 Vdc To -26 Vdc When Installed With Nonincendive Circuit Connected Per Installation Drawing 140979 At 12 MA Maximum Consumption, -23 Vdc To -26 Vdc With Barriers. Operation At A More Positive Voltage Than -23.5 Vdc Can Result In Reduced Linea |
Supply Sensitivity: | Less Than 2 MV Change In Output Voltage Per Volt Change In Input Voltage. |