Bently Nevada Vibration Monitoring System
-
Bently Nevada 3500 System
-
Endress Hauser Instruments
-
AB Modules
-
P+F Sensors
-
YOKOGAWA Transmitter
-
Emerson Rosemount Transmitter
-
Emerson Micro Motion Flow Meters
-
Emerson AMS Trex Device Communicator
-
MTL Safety Barrier
-
ABB TZID Valve Positioner
-
SIEMENS Simatic PLC
-
Siemens Building Automation
-
VEGA Instrumentation
-
AUMA Actuator
-
HACH Water Quality Meter
85mA AB Modules Flex 8 Point Thermocouple RTD Module 1794-IRT8

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xNput Signal Range | -40…100 MV DC For Thermocouples 0…325 MV DC For RTDs 0…500 Ω For Resistance Range | Accuracy Drift With Temperature | Hardware Only In MV Mode: 0.10% Full Scale MV Mode With Filtering: 0.05% Full Scale |
---|---|---|---|
External DC Supply Current, Nom | 85 MA @ 24V DC | Power Dissipation, Max | 3 W @ 31.2V DC |
Nput Resolution | 14 Bits | Temperature, Operating | -20…55 °C |
Highlight | 1794-IRT8 AB Modules,8 Point Thermocouple RTD Module,1794-IRT8 |
AB Flex 8 Point Thermocouple RTD Module 1794-IRT8
FLEX I/O is a small, modular I/O system for distributed applications that performs all functions of rack-based I/O. The FLEX system contains the following components shown:
• Adapter – Transfers read and write configuration data to and from the I/O module.
• Terminal base – Contains a terminal strip to terminate wiring for two- or three-wire devices.
• I/O module – Contains the bus interface and circuitry that is needed to perform specific functions that are related to your application.
Types of Modules
The module refers to the following catalogs:
Catalog Number |
Voltage |
Inputs |
Description |
1794-IRT8 | 24V DC | 8 | Analog – 8 pt, 16 bit non-isolated RTD, thermocouple, and mV Input module |
1794-IRT8XT | 24V DC | 8 | Analog – 8 pt, 16 bit non-isolated RTD, thermocouple, and mV Input module designed for extended temperature. |
The module accepts up to eight thermocouple or RTD inputs. The inputs are nonisolated and are selected with analog multiplexers. The inputs accept millivolt or resistive inputs. Default input spans are -40.00 mV… +100.00 mV or 0.0…500.0 Ω. Fault indicators are located field side.
No switches or jumpers are used on the TC and RTD Input module. The inputs have both fixed hardware filters and selectable firmware digital filters.
Related Part Number:
1794-IA8 |
1794-TB2 |
1794-OB8 |
1794-IA8I |
1794-TB3 |
1794-OB8EP |
1794-IA16 |
1794-TB3S |
1794-OB8EPXT |
1794-IM8 |
1794-TB3K |
1794-OB16 |
1794-IM16 |
1794-TB3SK |
1794-OB16D |
1794-OA8 |
1794-TBNK |
1794-OB16P |
1794-OA8I |
1794-TB3 |
1794-OB16PXT |
1794-OA16 |
1794-TB3K, |
1794-OB32P |
1794-OM8 |
1794-TB3SK |
1794-OC16 |
1794-OM16 |
1794-TBNK |
1794-OG16 |
1794-TBN |
1794-TBN |
1794-OV16 |
1794-TBKD |
1794-TB3S |
1794-OV16P |
1794-IB8 |
1794-IC16 |
1794-OV32 |
1794-IB16 |
1794-IG16 |
1794-OW8 |
1794-IB16D |
1794-IH16 |
1794-OW8XT |
1794-IB16XT |
1794-IV16 |
1794-IV32 |
1794-IB10XOB6 |
1794-IB32 |
1794-IB32K |
1794-IB10XOB6XT |
1794-IB16XOB16P |
1794-IF41 |