Sensitivity 10.2 MV/m/s2 (100 MV/g) ±5%. Acceleration Range 490 M/s2 (50 G) Peak Overall Acceleration Within The 10 Hz To 15 KHz Frequency Span. Vibration At Frequencies Above 15 KHz, Especially At The Transducers Resonance Will Significantly Decrease This Range.
Amplitude Linearity ±1% To 490 M/ S2 (50 G) Peak. Broadband Noise Floor (10 Hz To 15 KHz) 0.039 M/s2 (0.004 G) Rms.
Frequency Response 10 Hz To 15 KHz (600 Cpm To 900,000 Cpm) ±3dB; 30 Hz To 10 KHz (1800 Cpm To 600,000 Cpm) ±10% Temperature Sensitivity -11% To +3% Typical Over The Operating Temperature Range.
Highlight

330400 Machinery Condition Monitoring

,

Bently Nevada 330400

,

Bently Nevada Machinery Condition Monitoring

Leave a Message
Product Description

Bently Nevada Machinery Condition Monitoring 330400

These accelerometers are intended for critical machinery applications where casing acceleration measurements are required, such as gear mesh monitoring. The 330400 is designed to address the requirements of American Petroleum Institute Standard 670 for accelerometers. It provides an amplitude range of 50 g peak and a sensitivity of 100 mV/g. The 330425 is identical except it provides a larger amplitude range (75 g peak) and a sensitivity of 25 mV/g.

 

330400 Accelerometer

 

330400-AA-BB

 

A: Mounting Thread Option  
01 ¼-28 UNF integral stud
02 M8 X 1 integral stud
B: Agency Approval Option  
00 None
05 Multiple approvals (CSA, ATEX, IECEx,)

 