0 – 50kHz MTL Safety Barrier MTL5532 Pulse Isolator 35Vdc
Number Of Channels: | One, Fully Floating |
---|---|
Sensor Type: | Switch Or Proximity Detector (NAMUR/BS EN 60947–5–6:2001) 2– Or 3–wire Voltage Or Pulse Transmitter |
Location Of Switch: | Zone 0, IIC, T6 Hazardous Area Div. 1, Group A, Hazardous Location |
MTL5521 MTLx521 SOLENOID ALARM DRIVER CE
Number Of Channels: | One |
---|---|
Input Voltage: | 20 To 35V Dc |
Response Time: | Output Within 10% Of Final Value Within 100ms |
MTL4852 MTL Safety Barrier Secondary Interface Module
Number Of HART Channels: | 16 (ch17 To Ch256 In 16 Channel Groups) |
---|---|
Channel Device Type: | HART Rev 5-7 |
Channel Interface: | 2 Connections To Each Channel |
500Hz To 10kHz MTL4546Y Isolating Driver 16V 20mA ODM
Number Of Channels: | One |
---|---|
Location Of I/P Converter: | Zone 0, IIC, T4–6 Hazardous Area If Suitably Certified Div. 1, Group A, Hazardous Location |
Digital Signal Bandwidth: | 500Hz To 10kHz |
HART MTL4541 MTL Safety Barrier Repeater Power Supply
Number Of Channels: | One |
---|---|
Location Of Transmitte: | Zone 0, IIC, T4–6 Hazardous Area If Suitably Certified Div. 1, Group A Hazardous Location |
Safe-area Circuit Ripple: | < 50µA Peak-to-peak |
MTL5516C Switch MTL Safety Barrier Proximity Detector Interface 35mA 24V
Number Of Channels: | Two |
---|---|
Location Of Switches: | Zone 0, IIC, T6 Hazardous Area Div. 1, Group A Hazardous Location |
Hazardous-area Inputs: | Inputs Conforming To BS EN60947–5–6:2001 Standards For Proximity Detectors (NAMUR) |
MTL4521/L MTL5521 One-Channel Solenoid/Alarm Driver with 24V Maximum Output Voltage
Number Of Channels: | One |
---|---|
Location Of Load: | Zone 0, IIC, T4–6 Hazardous Area If Suitably Certified Div. 1, Group A Hazardous Location |
Input Voltage: | 20 To 35V Dc |
MTL5014 Switch/Proximity Detector Interface NAMUR/DIN 19234 Standards for Hazardous Area
Number Of Channels: | One |
---|---|
Location Of Switches: | Zone 0, IIC, T6 Hazardous Area Div. 1, Group A Hazardous Location |
Location Of Proximity Detectors: | Zone 0, IIC, T4–6 Hazardous Area If Suitably Certified Div. 1, Group A Hazardous Location |
MTL5044 IIC Isolated Safety Barrier with Safe-Area Circuit Ripple 125µA Peak-to-Peak
Number Of Channels: | Two |
---|---|
Location Of Transmitters: | Zone 0, IIC, T4–6 Hazardous Area If Suitably Certified Div. 1, Group A Hazardous Location |
Signal Range:: | 4 To 20mA |