40mm Endress Hauser Instruments Digital Oxygen Sensor Oxymax COS61D-AAA1A3
Product Details:
Place of Origin: | Germany |
Brand Name: | Endress+Hauser |
Certification: | CSA Gen. Purpose. |
Model Number: | COS61D-AAA1A3 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 piece |
---|---|
Price: | negotiable |
Packaging Details: | standard carton packing |
Delivery Time: | on request |
Payment Terms: | T/T |
Supply Ability: | 100pcs per month |
Detail Information |
|||
Material: | Sensor Shaft: Stainless Steel 1.4435 Membrane Cap: POM | Dimension: | Diameter: 40 Mm (1.57 Inch) Shaft Length: 186 Mm (7.32 Inch) |
---|---|---|---|
Measuring Principle: | Oxygen-sensitive Molecules (marker) Are Integrated In An Optical Active Layer (fluorescence Layer). The Fluorescence Layer Surface Is In Contact With The Medium. The Sensor Optics Are Directed At The Back Of The Fluorescence Layer. The Sensor Optics Transm | Application: | Aeration Tank, River Monitoring, Water Treatment, Fish Farming |
Characteristic: | Digital, Optical Measurement Of Dissolved Oxygen Based On Fluorescence Quenching Measurement Possible In Still Water | Design: | Calibration Data Saved In Sensor High Degree Of EMC Protection |
Process Temperature: | -5 To 60 °C (20 To 140 °F) | Temperature Sensor: | NTC 30K |
Highlight: | 40mm Endress Hauser Instruments,1.57 inch Endress Hauser Instruments,COS61D AAA1A3 |
Product Description
Endress Hauser Digital oxygen sensor Oxymax COS61D-AAA1A3
SPECIFICATIONS
-
Measuring principle:Optical oxygen measurement
-
Application:Aeration tank, river monitoring, water treatment, fish farming
-
Characteristic:Digital, optical measurement of dissolved oxygen based on fluorescence quenching Measurement possible in still water
-
Measurement range:0 to 20 mg/l;0 to 200 %SAT;0 to 400 hPa
-
Measuring principle:Oxygen-sensitive molecules (marker) are integrated in an optical active layer (fluorescence layer). The fluorescence layer surface is in contact with the medium. The sensor optics are directed at the back of the fluorescence layer. The sensor optics transmit green light pulses to the fluorescence layer. The markers respond (fluoresce) with red light pulses. The duration and intensity of the response signals depend directly on the oxygen contents or partial pressure.
-
Design:Calibration data saved in sensor:High degree of EMC protection
-
Material:Sensor shaft: stainless steel 1.4435;Membrane cap: POM
-
Dimension:Diameter: 40 mm (1.57 inch);Shaft length: 186 mm (7.32 inch)
-
Process temperature:-5 to 60 °C(20 to 140 °F)
-
Process pressure:Max. 10 bar abs(Max. 145 psi)
-
Temperature sensor:NTC 30K
-
Connection:Process connection: G1, NPT 3/4";Cable connection: fixed cable or TOP68 plug-in-head
Field of application
Oxymax COS61D is a high-performance, digital oxygen sensor that offers fast, accurate and drift-free measurement. It supports your process with low maintenance, high availability and easy handling. The sensor's long-term stable fluorescence layer is exclusively oxygen-selective (interference-free), ensuring consistently reliable measurement. Thanks to Memosens digital technology, the Oxymax COS61D combines maximum process and data integrity, and facilitates simple lab calibration.
Oxymax COS61D measures the dissolved oxygen concentration in:
-
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring -
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas -
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring -
Fish farming:
- O2 control for optimum growth conditions
Benefits
-
Minimum maintenance, maximum availability
-
Fast, drift-free measurement for precise aeration control and process monitoring
-
Long-term stability for increased process safety
-
Outstanding performance in all aeration processes (SBR, Anamox, etc.)
-
Chemical-free: no electrolyte handling
Related Part Number:
CM442-AAM1A2F011A+AK |
CYK10-G101 |
CYK10-G051 |
COY31-Z |
FMU30-AAHEABGHF |
COS61D-AAA1A4 |
CYK10-E051 |
CPS71D-7TB2G |
CLM253-CD0005 |
CM442-AAM1A2F010A |
FTW31-A2A5AA0A+1 L:600MM |
CPS31-1AC2ESA |
CPS31-1EC2ESA |
DK9CM-2 |
FTL41-AAA2AAAAA2CJAAAAJ L=1000MM |
CPS11-2AA2ESK |
FTM51-AGJ2L4A12AA L=2600MM |
PMP71-AAA2H21GAAAA |
CLM253-ID0005 |
COV45-41TN1 |
CPS11-2BA2ESA |
CPS77E-BA6BBU2 |
CLM223-CD0520 |
CPM253-MR8010 |
CYK10-E101 |
RMA42-AAD+F1H3Z2 |
CM442-AAM1A2F010BZ1 |
CPS11E-AA7BAA2 |
TM131-NDBDJHC4BA5CICB1AH3BA1 |
TM131-NDBDJHC4BA8CICB1AH3BA1 |
CPM253-MR8505 |
71512570 |
TMR35-A1BBADAG1AAA |