396-54-62 Emerson Rosemount Transmitter Rosemount 396 Submersion/Insertion Ph Sensor

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMeasurements And Ranges | PH: 0 To 14 | Available PH ACCUGLASS Types | GPHT Hemi Bulb Or GPHT Flat Bulb |
---|---|---|---|
Wetted Materials | 316 Stainless Steel, Polypropylene, EPDM, Glass | Process Connection | None, Use 1 In (25 Mm) NPT Process Connector, PN 23166-00 Or 23166-01 (sold Separately) |
Temperature Range | 32.0 °F (0 °C) To 212.0 °F (100 °C) | Pressure Range-hemi Bulb | 0 Psig (0.00 Barg) To 150 Psig (10.34 Barg) |
Pressure Range-flat Bulb | 0 Psig (0.00 Barg) To 100 Psig (6.89 Barg) | Weight/shipping Weight | 1 Lb (0.5 Kg)/2 Lb (0.9 Kg) |
Highlight | 396-54-62 Emerson Rosemount Transmitter,SS316 Emerson Rosemount Transmitter,Rosemount 396 |
Rosemount 396 Submersion/Insertion pH Sensor 396-54-62
TUpH sensors for your tough pH/oxidation reduction potential (ORP) applications
Rosemount TUpH pH/ORP sensors are robust sensors designed to meet a number of difficult application requirements. Sensors feature a variety of options suited to meet a number of installation requirements and are ideal for use in dirty, abrasive, coating, and high solid applications.
Rosemount 396 ordering information
Model
Code | Description |
396 | pH sensor: TUpH® insertion/submersion/flow-through |
Cable termination
Code | Description |
54 | For use with Rosemount 56, 1056, 1066, 1057, and 5081 |
Option 1
Code | Description |
_ | No selection, standard 15 ft (4.57 m) cable |
62 | Cable without BNC for direct wiring to Rosemount 56, 1056, 1057, 1066, and 5081 |
07 | Without preamplifier, 4 ft (1.22 m) cable |
08 | Without preamplifier, 10 ft (3.05 m) cable |
Option 2
Code |
Description |
_ |
No selection |
71 |
GPHT flat bulb |
Calibration and conformance certificates - optional level
Code |
Description |
CC |
Certificate of Calibration (no test data given) |
LC |
Loop Calibration Certificate (sensor and transmitter calibrated together with test data) |
EC |
Electronic Calibration Certificate (sensor calibrated against factory instrument with test data) |
Related Part Number:
1056-01-22-38-AN |
1056-01-25-38-AN |
1056-02-20-38 |
1056-03-22-32-AN |
1056面板 |
1057-02-20-32-42 |
1066-CL-HT-73 |
1066-P-HT-73 |
3900-01-10 |
3900-02-103 |
3900-10-01 |
3900VP-01-10 |
4847B61G01 |
5081-P-HT-20-73 |
21501-08 |
23242-02 |
23294-00-99 |
23502-08 |
23554-00 |
23820-00 |
24091-00 |
24263 |
33521-00 |
33523-00 |
211001L1NAQ4 |
499ACL-01-54-VP |