• Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range
  • Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range
  • Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range
Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range

Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range

Product Details:

Place of Origin: India
Brand Name: MTL
Certification: CE
Model Number: MTL5082

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Price: negotiable
Packaging Details: standard carton packing
Delivery Time: on request
Payment Terms: T/T
Supply Ability: 100pcs per month
Get Best Price Contact Now

Detail Information

Number Of Channels: One Location Of RTD: Zone 0, IIC, T4 Hazardous Area Div 1, Group A Hazardous Location
Resistance Range: 10Ω To 400Ω RTD Excitation Current: 200µA Nominal
Output Configuration: 2, 3 Or 4 Wires (independent Of Mode Selected For Hazardous-area Terminals Output Range: 10Ω To 400Ω (from A 100µA To 5mA Source)
Highlight:

MTL5082 Isolated Safety Barrier

,

MTL Isolated Safety Barrier

Product Description

MTL Isolated Safety Barrier MTL5082

 

The MTL5082 connects to a 2-, 3-, or 4-wire resistance temperature device (RTD) or other resistance located in a hazardous area, isolates

it and repeats the resistance to a monitoring system in the safe area. The module is intended typically (but not exclusively) for use with Pt100

3-wire RTDs. Switches located on top of the module allow selection of 2-, 3-, or 4-wire RTD connection. The MTL5082 should be considered

as an alternative, non-configurable MTL5074, for use in RTD applications where a resistance input is preferred or needed instead of 4/20mA.

The design is notable for its ease of use and repeatability. The number of wires which can be connected on the safe-area side of the unit is independent of the number of wires which can be connected on the hazardous-area side. The module drives upscale in the case of open-circuit detection.

 

MTL5521

MTL4546Y

MTL5501-SR

MTL5510

MTL5522

MTL4549Y

MTL5511

MTL5513

MTL5531

MTL4573

MTL5514D

MTL5516C

MTL5532

MTL4575

MTL5521/5521-T

MTL5522

MTL5541

MTL4646Y

MTL5523V

MTL5523VL

MTL5541S

MTL4850

MTL5525

MTL5526

MTL5544

MTL4851

MTL5532

MTL5533

MTL5544D

MTL4852

MTL5541/MTL5541-T

MTL5541A

MTL5546

MTL5018

MTL5541S/5541S-T

MTL5544

MTL5546Y

MTL5032

MTL5544AS

MTL5544S

MTL5561

MTL5042

MTL5573

MTL5561

MTL5573

MTL5044

MTL5546

MTL5546Y/5546Y-T

MTL5575

MTL5049

MTL5575

MTL5576-RTD

MTL5582B

MTL5511

MTL5581

MTL5582/5582B

 
 
 
Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range 0
Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range 1

Want to Know more details about this product
I am interested in Upgrade Your Safety Measures MTL5082 MTL Isolated Safety Barrier 10Ω to 400Ω Output Range could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.