| Menşe yeri: | Amerika |
|---|---|
| Marka adı: | Bently Nevada |
| Sertifika: | CE |
| Model numarası: | 9200-06-02-10-00 |
| Belge: | D-Agent_1-_work-104-s-Uploa...26.pdf |
| Min sipariş miktarı: | 1 adet |
| Fiyat: | negotiable |
| Ambalaj bilgileri: | Standart karton paketleme |
| Teslim süresi: | 12-16 hafta |
| Ödeme koşulları: | T/T |
| Yetenek temini: | Ayda 100 adet |
| Hassasiyet: | 20 mV/mm/s (500 mV/in/s), düzgün şekilde sonlandırıldığında ve kalibrasyon açısına yönlendirildiğind | Kalibrasyon Yükü: | 10 kΩ Terminal "A" - "B" Çıkış "A" ve "B" pinleri üzerinden |
|---|---|---|---|
| Hassasiyet Sıcaklık Katsayısı: | %0,2/°C | Dinamik çalışma aralığı: | 2,54 mm (0,100 inç) tepeden tepeye maksimum yer değiştirme |
| hız aralığı: | 25 mm/s (1 inç/s) (10 kΩ yük ile 100 Hz'de +22 °C gövde titreşiminde. | bobin direnci: | 1,25 kΩ ±5% |
| Vurgulamak: | 9200 Seismoprobe Velocity Transducers,Bently Nevada Seismoprobe Velocity Transducers |
||
Bently Nevada 9200 Seismoprobe Velocity Transducers
Bently Nevada Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The two-wire systems consist of a transducer and appropriate cable. The Seismoprobe family of velocity transducers is a two-wire design that uses moving-coil technology. It provides a voltage output directly proportional to the transducer's vibration velocity. Moving-coil transducers are less sensitive to impact or impulsive excitation than solid-state velocity transducers, which are inherently accelerometers with embedded integration electronics. Moving-coil transducers are less sensitive to impact or impulsive excitation and can represent a good choice for certain applications. Because they don’t require external power, they are convenient for portable measurement applications.
Ordering Information
Two-wire Transducer
9200-AA-BB-CC-DD
A: Transducer Mounting Angle/Minimum Operating Frequency Option | |
01 | 0 ±2.5, 4.5 Hz (270 cpm) |
02 | 45 ±2.5, 4.5 Hz (270 cpm) |
03 | 90 ±2.5, 4.5 Hz (270 cpm) |
06 | 0 ±100, 10 Hz (600 cpm) |
09 | 0 ±180, 15 Hz (900 cpm) |
B: Connector/Cable Option | |
01 | Top Mount (no cable) |
02 | Side Mount (no cable) |
05 | Terminal block top mount (no cable) |
10 through 50 | |
10 | 10 feet (3.0 meter) |
15 | 15 feet (4.6 meter) |
22 | 22 feet (6.7 meter) |
32 | 32 feet (9.8 meter) |
50 | 50 feet (15.2 meter) |
C: Mounting Base Option | |
01 | Circular; 1/4-20 UNC stud |
02 | Circular; 1/4-28 UNF stud |
03 | Rectangular flange |
04 | Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle |
05 | No base; 1/2-20 UNF-3A stud |
06 | Isolated circular 1/4-20 UNC stud |
07 | Isolated circular 1/4-28 UNF stud |
08 | Isolated rectangular flange |
09 | Isolated circular 5/8-18 UNF stud |
10 | Circular; M10X1 stud |
11 | Isolated circular M10X1 |
12 | Isolated circular 1/2-20 UNF-2A |
D: Agency Approval Option | |
00 | No Approvals |
01 | CSA |
04 | ATEX/IECEx |
![]()
![]()