Labeling: | Space For Labeling At The Front | Safety Integrity Level (SIL): | SIL 3 |
---|---|---|---|
Degree Of Protection: | IEC 60529:2001 | Supply Connection: | Terminals 17+, 18- |
Ambient Temperature: | -20 ... 60 °C (-4 ... 140 °F) | Dimensions: | 40 X 107 X 115 Mm (1.6 X 4.2 X 4.5 Inch) (W X H X D) , Housing Type C1 |
Highlight: | SIL 3 Multiplexer Master,Multiplexer Master,KFD2-HMM-16 |
16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC/EN 61508
Technical Data
Functional safety related parameters |
||
---|---|---|
Safety Integrity Level (SIL) |
SIL 3 |
|
Supply |
||
Connection |
terminals 17+, 18- |
|
Rated voltage |
20 ... 32 V DC typical at 100 mA |
|
Power consumption |
max. 3 W |
|
HART signal channels (non-intrinsically safe) |
||
Conformity |
HART field device input (revision 5 to 7) |
|
Connection |
26-pin flat cable for analog connections |
|
Leakage current |
< 3 µA at -20 ... 85 °C (-4 ... 185 °F) |
|
Terminating resistor |
external 230 ... 500 Ω standard (up to 1000 Ω possible) |
|
Output voltage |
≥ 400 mV ss (with the terminator resistance specified above) |
|
Output resistance |
100 Ω or smaller, capacitive coupling |
|
Input impedance |
according to HART specification |
|
Input voltage range |
0.08 ... 4 V ss ; typ. ± 5.2 V as local reference |
|
Interface |
||
Transfer rate |
9600, 19200, or 38400 Bit/s (selectable with DIL switch (2 and 3) by the user) |
|
Type |
RS-485 , 2-wire multidrop |
|
Address selection |
One of 31 possible addresses selectable per DIL switch (4 ... 8) |
|
Indicators/settings |
||
Control elements |
DIP switch |
|
Configuration |
via DIP switches |
|
Labeling |
space for labeling at the front |
|
Directive conformity |
||
Electromagnetic compatibility |
|
|
|
Directive 2014/30/EU |
EN 61326-1:2013 (industrial locations) |
Conformity |
||
Degree of protection |
IEC 60529:2001 |
|
Ambient conditions |
||
Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
|
Mechanical specifications |
||
Degree of protection |
IP20 |
|
Connection |
screw terminals |
|
Mass |
approx. 250 g |
|
Dimensions |
40 x 107 x 115 mm (1.6 x 4.2 x 4.5 inch) (W x H x D) , housing type C1 |
|
|
Height |
107 mm |
|
Width |
40 mm |
|
Depth |
115 mm |
Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
|
Data for application in connection with hazardous areas |
||
Certificate |
PF 07 CERT 1143 X |
|
|
Marking |
|
Directive conformity |
|
|
|
Directive 2014/34/EU |
EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
Related Models:
KCD2-STC-EX1.20 |
K-HM26-2M-261533 |
KFD2-SR2-Ex1.W.LB |
NBB15-U1-E2 |
KFD2-SR2-2.W.SM |
NBB1,5-5GM25-E2 |
KFD2-SR2-Ex2.W.SM |
NBB1,5-5GM25-E2-V3 |
KFD2-SR2-Ex2.2S |
NBB1,5-F79-E0 |
KFD2-SR2-2.2S |
NBB1,5-F79-E2 |
KFA6-DWB-EX1.D |
NBB15-U1-Z2 |
KFA6-SR2-Ex2.W |
NBB5-18GM50-E2-V1 |
KFA6-SR-2.3L.FA |
NBB15-30GM30-E2-V1 |
KFA6-ER-1.5 |
NBB15-30GM50-A2-V1 |
NBB15-30GM50-E2 |
|
KFA6-ER-1.W.LB |
NBB15-30GM50-E2-M |
KFA6-ER-2.W.LB |
NBB15-30GM50-E2-V1 |
NBB15-30GM50-E2-V1-M |
|
KFA6-SR-2.3L.FA |
NBB8-18GM30-E2 |
KFA6-STR-1.24.4 |
NBB8-18GM30-E2-V1 |
KFD0-CS-Ex1.50P |
NBB8-18GM60-A2-V1 |
KFD2-SH-Ex1.T.OP |
NJ4-12GK-SN |
KFD2-SL2-EX2.B |
NJ5-18GK-N |
KFD2-SR2-EX1.W |
NJ5-18GK-N-150 |
KFD2-SR2-Ex2.W |
NJ5-18GM-N |
KFD2-STC5-1.2O |
NJ8-18GK-N |
KFD2-STC5-Ex1 |
RD0-FB-EX4 |
KFD2-STC5-Ex1.H |
RD0-TI-Ex8.FF.* |
HIC2031 |
Z787.F |