EJX110A Diff Pressure Sensor EJX110A-EMS5G-919DB/KS21/D4 Differential Pressure Measurement

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOutput Signal | 4 To 20 MA DC With Digital Communication (HART 5 Protocol) | Measurement Span (capsule) | 0.5 To 100 KPa (2 To 400 InH2O) |
---|---|---|---|
Process Connections See The Table In The Next Page For The Codes For A Diaphragm Seal System. | Without Process Connector (1/4 NPT Female On The Cover Flanges) | Bolts And Nuts Material | 316L SST |
Installation | Horizontal Piping And Left Side High Pressure | Amplifier Housing | Cast Aluminum Alloy |
Electrical Connection | M20 Female, Two Electrical Connections And A Blind Plug | Integral Indicator | Digital Indicator |
Highlight | EJX110A diff pressure sensor,diff pressure sensor 0.5kPa,100kPa differential pressure measurement |
EJX110A Differential Pressure Transmitter EJX110A-EMS5G-919DB/KS21/D4
The EJX-A series is Yokogawa's premium performance line of DPharp transmitters. Released in 2004, it offers the performance and stability needed in demanding applications. The EJX-A series performance makes it the thoroughbred of the DPharp family of pressure transmitters.
The EJX110A is the traditional-mount Differential Pressure Transmitter in the series.
EJX110A features include:
- ± 0.04% Accuracy (0.025% Accuracy option available)
- ± 0.1% per 15 years Stability
- 90 ms Response Time
- 3,600 psi MWP
- Exida and TUV SIL2 / SIL3 Certified
- Local Parameter Setting (LPS)
EJX110A Specification Overview
Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications.
Measurement Types | |
---|---|
Primary Variable | Differential Pressure |
Secondary Variable | Static Pressure |
Reference Accuracy | |
Primary Variable | ±0.04% of Span ±0.025% of Span available |
Secondary Variable | ±0.2% of Span |
Response Time | |
Primary Variable | 90 msec |
Secondary Variable | 360 msec |
Long Term Stability | |
Primary Variable | ±0.1% of URL per 15 years |
Over-pressure effect | |
Primary Variable | ±0.03% of URL |
Rangeability | |
Primary Variable | 200:1 |
Related Part Number:
EJA120E-JES4G-912DB |
EJA120E-JES4J-812EB |
EJA120E-JES5G-934DJ/KU22/M01/D4/N4 |
EJA130E-JMS4G-712DD/D4 |
EJA130E-JMS5J-917DB/C1/X2 |
EJA130E-JHS4J-817EB/FF1/D4 |
EJA130E-JHS4J-817EB/FU1/D4 |
EJA130E-JMS5J-719DC/NS21/N4 |
EJA130E-EMS5B-99DA/X1/D4/M01/T09 |
EJA130E-JMS4G-91DDJ/KS21/X2/HC/N4 |
EJA130E-FHS5G-919DB/X2/D4/M01/T09/KS26 |
EJA130E-FMS5G-919DB/X2/D4/M01/T09/KS26 |
EJA130E-JMS5G-719DD/X2/D4/M01/T09/KU22 |
EJA130E-FMS5G-919DB/X2/D4/M01/T09/KS26 |
EJA130E-FMS5G-919DB/KS26/X2/D4/M01/T09 |
EJA210E-JMS4J-912DN-EJ14A2SE01-B |
EJA210E-JMS5J-912NN-WA13A1SW00-B/D4 |
EJA210E-DMS4J-912DN-EJ14A2SE01-B/D4 |