Bently Nevada Vibration Monitoring System
-
Bently Nevada 3500 System
-
Endress Hauser Instruments
-
AB Modules
-
P+F Sensors
-
YOKOGAWA Transmitter
-
Emerson Rosemount Transmitter
-
Emerson Micro Motion Flow Meters
-
Emerson AMS Trex Device Communicator
-
MTL Safety Barrier
-
ABB TZID Valve Positioner
-
SIEMENS Simatic PLC
-
Siemens Building Automation
-
VEGA Instrumentation
-
AUMA Actuator
-
HACH Water Quality Meter
P+F Read Head WCS3B-LS221 Max. 314.5m Measuring Range

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xPassage Speed | ≤ 12.5 M/s | Measuring Range | Max. 314.5 M |
---|---|---|---|
Free Tolerances To Code Rail | Horizontal: 31 Mm ( ± 15.5 Mm ) Vertical: 28 Mm ( ± 14 Mm ) | Resolution | ± 0.4 Mm (1,250 Positions/m) |
Operation Indicator | LED Green: Power On | Data Flow Indicator | LED Yellow: Data Communication Active |
Operating Voltage | 10 ... 30 V DC | Power Consumption | 2 VA |
Highlight | P+F Read head,Read head WCS3B-LS221 |
Read head WCS3B-LS221
Read head, RS-485 interface, with RS-485 termination resistor
-
RS-485 interface
-
Non-contact, absolute position encoder
-
Automatic detection of dirt accumulation
Datasheet excerpt: Technical data of WCS3B-LS221
General specifications |
||
---|---|---|
Passage speed |
≤ 12.5 m/s |
|
Measuring range |
max. 314.5 m |
|
Free tolerances to code rail |
horizontal: 31 mm ( ± 15.5 mm ) |
|
Resolution |
± 0.4 mm (1,250 positions/m) |
|
Functional safety related parameters |
||
MTTFd |
236 a |
|
Mission Time (TM) |
20 a |
|
Diagnostic Coverage (DC) |
0 % |
|
Indicators/operating means |
||
Operation indicator |
LED green: power on |
|
Data flow indicator |
LED yellow: data communication active |
|
Error indicator |
LED red |
|
Electrical specifications |
||
Operating voltage |
10 ... 30 V DC |
|
Power consumption |
2 VA |
|
Interface |
||
Interface type |
RS 485 interface |
|
Data output code |
binary code |
|
Protocol |
1 , 2 |
|
Transfer rate |
62.5 kBit/s |
|
Address |
0 |
|
Termination |
with RS 485 termination |
|
Standard conformity |
||
Emitted interference |
DIN EN 61000-6-4 , DIN EN 12015 |
|
Noise immunity |
DIN EN 61000-6-2 , DIN EN 12016 |
|
Shock resistance |
DIN EN 60068-2-27, half sine 30 g, 18 ms |
|
Vibration resistance |
DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
|
Approvals and certificates |
||
CSA approval |
cCSAus Certified, General Purpose |
|
CCC approval |
CCC approval / marking not required for products rated ≤36 V |
|
Ambient conditions |
||
Operating temperature |
0 ... 60 °C (32 ... 140 °F) |
|
Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
|
Relative humidity |
90 % , noncondensing |
|
Mechanical specifications |
||
Connection type |
5-pin, M12 x 1 connector |
|
Degree of protection |
IP54 |
|
Material |
|
|
|
Housing |
ABS , PC (Polycarbonate) |
Mass |
500 g |
|
General information |
||
Ordering information |
Mounting plate included with delivery |