Bently Nevada Vibration Monitoring System
-
Bently Nevada 3500 System
-
Endress Hauser Instruments
-
AB Modules
-
P+F Sensors
-
YOKOGAWA Transmitter
-
Emerson Rosemount Transmitter
-
Emerson Micro Motion Flow Meters
-
Emerson AMS Trex Device Communicator
-
MTL Safety Barrier
-
ABB TZID Valve Positioner
-
SIEMENS Simatic PLC
-
Siemens Building Automation
-
VEGA Instrumentation
-
AUMA Actuator
-
HACH Water Quality Meter
P+F Inductive Sensor NCN25-F35-A2-250-15M-V1 With Stainless Steel Amplifier Housing And Complementary Switching Function

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xSwitching Function | Complementary | Output Type | PNP |
---|---|---|---|
Output Polarity | DC | Amplifier Housing | Stainless Steel |
Cable Length | L = 15 M | Dimensions | 40mm*44mm*56mm |
Highlight | NCN25-F35-A2-250-15M-V1,Inductive sensor NCN25-F35-A2-250-15M-V1,Complementary Switching Inductive sensor |
P+F Inductive sensor NCN25-F35-A2-250-15M-V1
Technical Data
General specifications |
||
Switching function |
|
complementary |
Output type |
|
PNP |
Rated operating distance |
sn |
25 mm |
Installation |
|
flush mountable |
Output polarity |
|
DC |
Assured operating distance |
sa |
0 ... 20 mm |
Reduction factor rAl |
|
0.5 |
Reduction factor rCu |
|
0.5 |
Reduction factor r304 |
|
0.6 ... 1 |
Output type |
|
4-wire |
Mounting angle |
|
Al |
Amplifier housing |
|
Stainless steel |
Nominal ratings |
||
Operating voltage |
UB |
10 ... 30 V |
Switching frequency |
f |
0 ... 20 Hz |
Hysteresis |
H |
0.3 ... 5 typ. 2 % |
Reverse polarity protection |
|
reverse polarity protected |
Short-circuit protection |
|
pulsing |
Voltage drop |
Ud |
≤ 3 V |
Operating current |
IL |
0 ... 200 mA |
No-load supply current |
I0 |
≤ 25 mA |
Time delay before availability |
tv |
≤ 20 ms |
Switching state indicator |
|
Multihole-LED, yellow |
Functional safety related parameters |
||
MTTFd |
|
7515 a |
Mission Time (TM) |
|
20 a |
Diagnostic Coverage (DC) |
|
0 % |
Compliance with standards and directives |
||
Standard conformity |
|
|
Standards |
|
EN IEC 60947-5-2 |
Approvals and certificates |
||
UL approval |
|
cULus Listed, General Purpose, Class 2 Power Source |
CCC approval |
|
CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
||
Ambient temperature |
|
0 ... 250 °C (32 ... 482 °F) |
Mechanical specifications |
||
Connection type |
|
Connector plug M12 x 1 , 4-pin |
Cable version |
|
PFA cable, with armour of stainless steel |
Core cross section |
|
3 x 0.34 , screened |
Housing material |
|
PTFE / Al / 1.4305 / AISI 303 |
Sensing face |
|
PTFE |
Degree of protection |
|
amplifier IP67 sensor IP40 |
Dimensions |
|
|
Height |
|
40 mm |
Width |
|
44 mm |
Length |
|
56 mm |
Cable length |
|
L = 15 m |
Note |
|
- amplifier 0 °C ... 70 °C - r1.4305 dep. on thickness of measurement plate d: r1.4305 = 1 for d < 1mm Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. |