Compact Ultrasonic Transmitter FMU40-ANB2A4 2-Wire HART Communication for Level Measurement

Contact me for free samples and coupons.
WhatsAPP:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMeasuring Principle | Ultrasonic | Characteristic / Application | Compact Ultrasonic Transmitter |
---|---|---|---|
Supply / Communication | 2-wire HART | Accuracy | +/- 2 Mm Or +/- 0.2 % Of Set Measuring Range |
Ambient Temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) | Communication | 4...20 MA HART |
Highlight | 2-Wire HART Communication Ultrasonic Transmitter,Compact Ultrasonic Transmitter,FMU40-ANB2A4 Ultrasonic Transmitter |
E+H Ultrasonic level meter FMU40-ANB2A4
The Prosonic FMU40 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Two-wire or four-wire instrument for continuous non-contact level and flow measurement.
-
Process connection: Thread
-
Temperature: -40 to +80°C (-40 to +176°F)
-
Pressure: +0.7 to +3bar (+10 to +44psi)
-
Maximum measuring distance: Liquids 5m (16ft), Solids 2m (16ft)
-
Blocking distance: Liquids and Solids 0.25m (0.8ft)
-
International explosion protection certificates
specifications
Measuring principle |
Ultrasonic |
Characteristic / Application |
Compact ultrasonic transmitter |
Supply / Communication |
2-wire HART |
Accuracy |
+/- 2 mm or +/- 0.2 % of set measuring range |
Ambient temperature |
-40 °C ... 80 °C (-40 °F ... 176 °F) |
Process temperature |
-40 °C ... 80 °C (-40 °F ... 176 °F) |
Process pressure / max. overpressure limit |
0.7 bar ... 3 bar abs (10 psi ... 44 psi) |
Main wetted parts |
PVDF |
Process connection |
G / NPT 1 1/2" |
Blocking distance |
0.25 m (0.8 ft) |
Max. measurement distance |
Liquids: 5 m (16 ft), Solids: 2 m (6.6 ft) |
Communication |
4...20 mA HART |
Certificates / Approvals |
ATEX, FM, CSA, IEC, INMETRO, NEPSI |
Application limits |
For higher resistance: FMU42/FDU9x Foam / high turbulence possible: FMU41/FDU91 Fast filling and discharging rate: FMU90 + FDU9x Level limit detection: FMU90 + FDU9x |